PHYO — PreciSe OpticsContact us ↗
Meniscus optical lenses

PRECISION OPTICS

Concave-convex lenses (Meniscus)

Meniscus lenses combine one concave surface and one convex surface. Their optical power can be positive or negative, depending on the surface curvatures, lens thickness and material.

A positive meniscus lens is thicker at the centre, while a negative meniscus lens is thinner at the centre. PHYO supplies custom meniscus lenses with materials, geometry and coatings selected for the optical design.

01SpecificationsCommercial and high-precision options

Meniscus lens specifications

Meniscus lens specifications
ParameterCommercialHigh precision
MaterialAs required: SCHOTT, CDGM and other optical glassesAs required: SCHOTT, CDGM and other optical glasses
Diameter tolerance+0.00 / −0.20 mm+0.00 / −0.05 mm
Focal length tolerance at 633 nmTypical ±5%Typical ±2%
CentrationTypical <3 arcminTypical <3 arcmin
Surface flatness at 632.8 nmλ/4λ/8
Surface quality (scratch–dig)80–5040–20
Bevel0.2–0.50.05–0.2
Coating / finishingAs required; painting and protective coatingsAs required; painting and protective coatings
02Product drawingLens profile and dimensional symbols

Meniscus lens geometry

Meniscus lens cross-section and front view with diameter D, centre thickness CT, edge thickness ET and surface radii R1 and R2
03Coating curveAnti-reflective coating design

Anti-reflective coating response

Qualitative anti-reflective coating response across a design band without measured spectral values